Add to Cart
Custom Heat Recovery Air Cooled Water Chiller Air Conditioner Chiller
Model HLWA~ | 380DHM | 420DHM | 480DHM | 520DHM | 560DHM | 620DHM | 680DHM | |||||||||
Rated Cooling Capacity | X 1000Kcal/h | 307.8 | 336.2 | 399.0 | 421.3 | 460.9 | 503.9 | 543.4 | ||||||||
KW | 358 | 391 | 464 | 490 | 536 | 586 | 632 | |||||||||
Comp. lnput Power×Qty (KW) | 58.2×2 | 63.8×2 | 70.5×2 | 74.1×2 | 82.4×2 | 90.2×2 | 98.9×2 | |||||||||
Refrigerant | R407C | |||||||||||||||
Power Supply | 380V/ 3ph/ 50Hz | |||||||||||||||
Safety Protection | Phase reversion protection, Phase lack protection, Overload current protection, Low & High pressure protection, Low temp. protection, Water flow protection. | |||||||||||||||
Number of Refrigeration Circuit | 2 | |||||||||||||||
Capacity Control (%) | 0, 25, 37.5, 50, 62.5, 75, 87.5, 100 | |||||||||||||||
Refrigerant Charge (Kg) | 104 | 112 | 136 | 142 | 156 | 168 | 186 | |||||||||
Condenser | Ripple Aluminum Fins Around Copper Pipe | |||||||||||||||
| Dia.of Pipe (inch) | 5" | 5" | 3"×2 | 3"×2 | 4"×2 | 4"×2 | 4"×2 | ||||||||
Water Side Max Pressure (MPa) | 1 | |||||||||||||||
Chilled Water Flow(m3/h) | 61.6 | 67.2 | 79.8 | 84.3 | 92.2 | 100.8 | 108.7 | |||||||||
Water Pressure drop (kPa) | 42 | 54 | 44 | 52 | 54 | 55 | 65 | |||||||||
Axial Fan | Air Flow×1000m3/h | 172.8 | 172.8 | 230.4 | 230.4 | 230.4 | 321.6 | 321.6 | ||||||||
Power×Qty (KW) | 1.2×12 | 1.2×12 | 1.2×16 | 1.2×16 | 1.2×16 | 2.0×16 | 2.0×16 | |||||||||
Running Noise dB(A) | 72 | 72 | 72 | 72 | 75 | 75 | 75 | |||||||||
| 4430 | 4550 | 5340 | 5420 | 5500 | 5860 | 6320 | |||||||||
| 4750 | 4970 | 5800 | 5950 | 6040 | 6480 | 6900 | |||||||||
|
|
|
|
|
|
|
|
|
| |||||||
Heat Recovery | ||||||||||||||||
Refrigerant Charge (Kg) | 110 | 118 | 142 | 148 | 160 | 174 | 192 | |||||||||
Heat Reclaimed Volume (kw) | X 1000Kcal/h | 92.3 | 100.9 | 119.7 | 126.4 | 138.3 | 151.2 | 163.0 | ||||||||
KW | 107 | 117 | 139 | 147 | 161 | 176 | 190 | |||||||||
| Dia.of Pipe (inch) | 2-1/2" | 2-1/2" | 2"×2 | 2"×2 | 2"×2 | 2"×2 | 2"×2 | ||||||||
Water Side Max Pressure (MPa) | 1 | |||||||||||||||
Reclaimed Water Flow (m3/h) | 18.5 | 20.2 | 23.9 | 25.3 | 27.7 | 30.2 | 32.6 | |||||||||
Water Pressure drop (kPa) | 26 | 26 | 27 | 27 | 30 | 30 | 34 | |||||||||
Total Weight (Kg) | 4790 | 4910 | 5920 | 6040 | 6260 | 6480 | 6980 | |||||||||
Running Weight(Kg) | 5280 | 5440 | 6500 | 6650 | 6760 | 7240 | 7720 |
Note :
1. Rated Cooling Capacity Based on: DB Temperature 35℃/WB Temperature 24℃ |
Chilled water inlet/outlet temp. 12℃/7℃, Fouling factor: 0.088㎡.°C/KW. |
2. Chilled Water Range: 5~20℃; Lowest Ambient Temperature:15℃~43℃; |
3. Heat recovery unit water in/out temperature: 50℃/55℃; |
4.Changes of Specification for lmprovement May Be made without Notice. |
Feature:
Advance control system, steady quality and reliable features.
1 . Micro-computer control intelligently, English display, and friendly interface. Operating information is clear at a glance.
2 . Micro-computer and electrical control elements are brand products and imported from world. The products has
good quality, and reliable features
3 . The components and system pipes layout reasonable.
4 . The unit uses high efficient heat exchanger. It adopts outdoor structure design and system matching with
small volume, lightweight, and less area occupied.
5 . High efficiency heat exchanger ,ecological refrigeration units , reduced energy consumption .