OEM Big Air Cooled Chiller Unit Industrial Air Coolers 111 KW - 337 KW
Model HLWH~ |
100SM |
150SM |
195SM |
230SM |
270SM |
290SM |
320SM |
|
100SHM |
150SHM |
195SHM |
230SHM |
270SHM |
290SHM |
320SHM |
||
Rated Cooling Capacity |
Cooling Capacity (KW) |
101 |
147 |
196 |
232 |
268 |
293 |
316 |
Comp. Input Power (KW) |
34.6 |
48.2 |
63.8 |
70.5 |
82.4 |
90.2 |
98.9 |
|
Rated Heating Capacity |
Heating Capacity (KW) |
111 |
159 |
212 |
245 |
284 |
311 |
337 |
Comp. Input Power (KW) |
34.1 |
47.4 |
62.8 |
69.2 |
80.8 |
88.4 |
97.2 |
|
Refrigerant |
R407C |
|||||||
Power Supply |
3φ-380V/50HZ |
|||||||
Safety Protection |
Phase reversion protection, Phase lack protection, Overload current protection, Low & High pressure protection, Low temp. protection, Water flow protection. |
|||||||
Number of Refrigeration Circuit |
1 |
|||||||
Capacity Control (%) |
0, 50, 75, 100 |
|||||||
Refrigerant Charge (Kg) |
30 |
42 |
56 |
68 |
78 |
84 |
93 |
|
Air Cooled Heat Exchanger |
Ripple Aluminum Fins Around Copper Pipe |
|||||||
Water Cooled Heat Exchanger |
Dia.of Pipe (inch) |
2-1/2" |
3" |
3" |
3" |
4" |
4" |
4" |
Water Side Max Pressure (MPa) |
1 |
|||||||
Chilled Water Flow(m3/h) |
17.4 |
25.3 |
33.7 |
39.9 |
46.1 |
50.4 |
54.3 |
|
Water Pressure Drop (kPa) |
28 |
33 |
48 |
55 |
61 |
64 |
66 |
|
Flow of Hot Water(m3/h) |
19.1 |
27.3 |
36.5 |
42.1 |
48.8 |
53.5 |
58.0 |
|
Axial Fan |
Air Flow ×1000m3/h |
56.8 |
80.4 |
113.6 |
115.2 |
115.2 |
160.8 |
160.8 |
Power×Qty (KW) |
1.2×4 |
2.0×4 |
1.2×8 |
1.2×8 |
1.2×8 |
2.0×8 |
2.0×8 |
|
Running Noise dB(A) |
75 |
75 |
75 |
75 |
75 |
75 |
75 |
|
Total Weight (Kg) |
1550 |
1960 |
2940 |
3120 |
3300 |
3480 |
3660 |
|
Running Weight(Kg) |
1660 |
2140 |
3160 |
3340 |
3550 |
3730 |
3980 |
Note :
1. Rated Cooling Capacity Based on: DB Temperature 35℃/WB Temperature 24℃ |
Chilled water inlet/outlet temp. 12℃/7℃, Fouling factor: 0.088㎡.°C/KW. |
2. Rated Cooling Capacity Based on: DB Temperature 7℃/WB Temperature 6℃ |
Hot water inlet/outlet temp. 40℃/45℃; Hot water range: 45℃~45℃; |
2. Chilled Water Range: 5~20℃; Lowest Ambient Temperature: -5℃~43℃; |
3. Heat recovery unit water in/out temperature: 50℃/55℃; |
4.Changes of Specification for lmprovement May Be made without Notice. |
Feature:
4) Air cooled type , no cooling tower needed
Services :
1 . Golden can supply OEM service for customers
2 . Produce heat pump according to customer's special demands
3 . Supply spare parts according to order quantity
4 . General testing and operational test carried out for every unit before delivery
5 . Long warranty period